1
0
mirror of https://github.com/opinkerfi/nagios-plugins.git synced 2024-11-10 04:23:44 +01:00
nagios-plugins/nsclient/trunk/scripts/wmi/check_counter_large_rawcount.vbs
Páll Guðjón Sigurðsson e03f590221 VB Scripts for WMI added
2010-05-31 11:03:56 +00:00

848 lines
29 KiB
Plaintext

' Copyright 2007 GroundWork Open Source Inc.
'
' This program is free software; you can redistribute it and/or
' modify it under the terms of the GNU General Public License
' as published by the Free Software Foundation; version 2
' of the License.
'
' This program is distributed in the hope that it will be useful,
' but WITHOUT ANY WARRANTY; without even the implied warranty of
' MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
' GNU General Public License for more details.
'
'
' Author Dr. Dave Blunt at GroundWork Open Source Inc. (dblunt@groundworkopensource.com)
'*************************************************************************************************
' Public Variable
'*************************************************************************************************
Const intOK = 0
Const intWarning = 1
Const intCritical = 2
Const intError = 3
Const intUnknown = 3
Dim argcountcommand
Dim arg(20)
Dim strComputer
Dim strClass
Dim strProp
Dim strInst
Dim warningValue
Dim warningValueString
Dim criticalValue
Dim criticalValueString
Dim strUser
Dim strPass
Dim strDomain
Dim strNameSpace
Dim strDescription
Dim strCommandName
Dim strResultTemp
Dim strResult
Dim strResult1
Dim strResult2
Dim intReturnTemp
Dim intReturn
Dim strResultTemp1
Dim strResultTemp2
Dim strResultTemp3
Dim strResultTemp4
Dim intReturnTemp1
Dim strPrefix
Dim intValue
Dim returnValue
Dim strPropName
Dim instanceArray()
Dim instanceArraySize
Dim warningArraySize
Dim criticalArraySize
Dim warningArray()
Dim criticalArray()
Dim instance
Dim propArray()
Dim propArraySize
Dim lWarningValue
Dim uWarningValue
Dim lCriticalValue
Dim uCriticalValue
Dim ArgCount
Dim strArgMain(10)
Dim strArgSortDes(10)
Dim strArgDetailDes(10)
Dim strArgExample(10)
Dim objWMIService, colWMI,objWMI,objSWbemLocator
strComputer=""
strClass = ""
strProp = ""
strInst = ""
warningValue = -1
criticalValue = -1
strUser = ""
strPass = ""
strDomain = ""
intReturnTemp1 = 0
'*************************************************************************************************
' Functions and Subs
'*************************************************************************************************
'-------------------------------------------------------------------------------------------------
'Function Name: f_Error.
'Descripton: Display an error notice include : Error Number and Error Description.
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_Error()
nbrError = err.number
if (nbrError <> 0 ) then
Select Case nbrError
Case 462, -2147023174
strExitMsg = "Timeout connecting to WMI on this host! Error Number: " & nbrError & " Description: " & err.description
Case -2147024891
strExitMsg = "Authentication failure to remote host! Error Number: " & nbrError & " Description: " & err.description
Case -2147217392
strExitMsg = "Error! Number: " & nbrError & " Description: Invalid Class"
Case Else
strExitMsg = "Error! Number: " & nbrError & " Description: " & err.description
End Select
wscript.echo strExitMsg
wscript.quit(intUnknown)
end if
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_Help.
'Descripton: Display help of command include : Description, Arguments, Examples
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_Help()
Dim str
str="Check Counter Large RawCount. If your Local Machine has the same Administrator account and password as the Remote Machine then you don't have to use the two last parameters."&vbCrlF&vbCrlF
str=str&"cscript check_counter_rawcount.vbs -h hostname -class classname -prop property -inst instancename [-w warning_level -c critical_level] [-user username -pass password [-domain domain]]"&vbCrlF
str=str&vbCrlF
str=str&"-h [--help] Help."&vbCrlF
str=str&"-h hostname Host name."&vbCrlF
str=str&"-class classname Class name."&vbCrlF
str=str&"-prop property Property of Class."&vbCrlF
str=str&"-inst instance Needed Instance."&vbCrlF
str=str&"-w warning_level Warning threshold."&vbCrlF
str=str&"-c critical_level Critical threshold."&vbCrlF
str=str&"-user username Account Administrator on Remote Machine."&vbCrlF
str=str&"-pass password Password Account Administrator on Remote Machine."&vbCrlF
str=str&"-domain domain Domain Name of Remote Machine."&vbCrlF
str=str&vbCrlF
str=str&"Example: cscript check_counter_large_rawcount.vbs -h Ser1 -class Win32_PerfRawData_PerfProc_Process -prop WorkingSet -inst ""*"" -w 30 -c 70 [-user Ser1\Administrator -pass password -domain ITSP] "
str=str&"Example: cscript check_counter_large_rawcount.vbs -h Ser1 -class Win32_PerfRawData_PerfProc_Process -prop WorkingSet -inst ""IDProcess = '3612', IDProcess = '2156'"" -w 30 -c 70 [-user Ser1\Administrator -pass password -domain ITSP] "
wscript.echo str
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetAllArg.
'Descripton: Get all of arguments from command.
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetAllArg()
On Error Resume Next
Dim i
argcountcommand=WScript.Arguments.Count
for i=0 to argcountcommand-1
arg(i)=WScript.Arguments(i)
next
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetOneArg.
'Descripton: Get an argument from command.
'Input: Yes.
' strName: Name of argument
'Output: Value.
'-------------------------------------------------------------------------------------------------
Function f_GetOneArg(strName)
On Error Resume Next
Dim i
for i=0 to argcountcommand-1
if (Ucase(arg(i))=Ucase(strName)) then
f_GetOneArg=arg(i+1)
Exit Function
end if
next
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetInstance.
'Descripton: Get infomation at Local Host.
'Input: instance.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetInstance(instance)
On Error Resume Next
strResultTemp1 = ""
strResultTemp2 = ""
strResultTemp = ""
intResultTemp = 0
strInstanceTemp1 = ""
strInstanceTemp2 = ""
intInstanceTemp1 = 0
intInstanceTemp2 = 0
'Depend on strInfo parameters to get the result value
if(instance = "*") then
strQuery = "Select " & strProp & " from " & strClass
Set colWMI = objWMIService.ExecQuery(strQuery)
else
intInstanceTemp1 = InStr(1,instance,"=")
strInstanceTemp1 = Mid(instance,1,intInstanceTemp1-1)
intInstanceTemp2 = Len(instance)
strInstanceTemp2 = Mid(instance,intInstanceTemp1+1,intInstanceTemp2-intInstanceTemp1)
instance=strInstanceTemp1 & "='" & strInstanceTemp2 & "'"
strQuery = "Select " & strProp & " from " & strClass & " where " & instance
Set colWMI = objWMIService.ExecQuery(strQuery)
end if
count = -1
count = colWMI.count
if(count = -1) then
Wscript.Echo "Unknown - No data received from WMI;"
Wscript.Quit(intUnknown)
else
if(colWMI.count > 0) then
f_FormatData(colWMI)
strResultTemp1 = strResultTemp1 & strResultTemp3
strResultTemp2 = strResultTemp2 & strResultTemp4
intReturnTemp = intReturnTemp1
Exit Function
else
strResultTemp1 = "Unknown - " & instance &" query: No row returned."
intReturnTemp = intUnknown
Exit Function
end if
end if
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetPrefix.
'Descripton: Get Prefix.
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetPrefix(intValue)
On Error Resume Next
strPrefix = ""
If(warningValue <> "" And criticalValue = "") Then
If (IsNumeric(warningValue)) Then
If (Int(intValue) < Int(warningValue)) Then
returnValue=0
strPrefix= "OK - "
Else
returnValue=1
strPrefix= "Warning - "
End If
Else
Wscript.Echo "Error! Arguments wrong, please verify -w parameter"
Wscript.Quit(intError)
Exit Function
End If
End If
If(warningValue = "" And criticalValue <> "") Then
If (IsNumeric(criticalValue)) Then
If (Int(intValue) < Int(criticalValue)) Then
returnValue=0
strPrefix= "OK - "
Else
returnValue=2
strPrefix= "Critical - "
End If
Else
Wscript.Echo "Error! Arguments wrong, please verify -c parameter"
Wscript.Quit(intError)
Exit Function
End If
End If
If (warningValue <> "" And criticalValue <> "") Then
If (IsNumeric(warningValue) And IsNumeric(criticalValue)) Then
if (Int(warningValue) < Int(criticalValue)) then
if (Int(intValue) < Int(warningValue)) then
returnValue=0
strPrefix= "OK - "
else
if (Int(intValue) < Int(criticalValue)) then
returnValue=1
strPrefix= "Warning - "
else
returnValue=2
strPrefix= "Critical - "
end if
end if
else
if (Int(intValue) > Int(warningValue)) then
returnValue=0
strPrefix= "OK - "
else
if (Int(intValue) > Int(criticalValue)) then
returnValue=1
strPrefix= "Warning - "
else
returnValue=2
strPrefix= "Critical - "
end if
end if
end If
Else
Wscript.Echo "Error! Arguments wrong, please verify -w -c parameter"
Wscript.Quit(intError)
Exit Function
End If
End If
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetPrefixWithRange.
'Descripton: Get Prefix.
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetPrefixWithRange(intValue)
On Error Resume Next
lWarningValue = ""
uWarningValue = ""
lCriticalValue= ""
uCriticalValue= ""
warningReturn = 0
criticalReturn = 0
If(warningValue <> "") Then
f_GetWarningValueFromRange(warningValue)
End If
If(criticalValue <> "") Then
f_GetCriticalValueFromRange(criticalValue)
End If
strPrefix = ""
'verify warning
If((lWarningValue <> "") And (uWarningValue <> "")) Then
If(Int(lWarningValue) <= Int(uWarningValue)) Then
If((Int(lWarningValue) >= Int(intValue)) Or (Int(intValue) >= Int(uWarningValue))) Then
warningReturn=1
End If
Else
If((Int(intValue) >= Int(uWarningValue) ) And (Int(intValue) <= Int(lWarningValue))) Then
warningReturn=1
End If
End If
End If
If((lWarningValue <> "") And (uWarningValue = "")) Then
If(Int(intValue) <= Int(lWarningValue)) Then
warningReturn=1
End If
End If
If((lWarningValue = "") And (uWarningValue <> "")) Then
If(Int(intValue) >= Int(uWarningValue)) Then
warningReturn=1
End If
End If
'verify critical
If((lCriticalValue <> "") And (uCriticalValue <> "")) Then
If(Int(lCriticalValue) <= Int(uCriticalValue)) Then
If((Int(lCriticalValue) >= Int(intValue)) Or (Int(intValue) >= Int(uCriticalValue))) Then
criticalReturn=2
End If
Else
If((Int(intValue) >= Int(uCriticalValue) ) And (Int(intValue) <= Int(lCriticalValue))) Then
criticalReturn=2
End If
End If
End If
If((lCriticalValue <> "") And (uCriticalValue = "")) Then
If(Int(intValue) <= Int(lCriticalValue)) Then
criticalReturn=2
End If
End If
If((lCriticalValue = "") And (uCriticalValue <> "")) Then
If(Int(intValue) >= Int(uCriticalValue)) Then
criticalReturn=2
End If
End If
'return result
If(criticalReturn = 2) Then
returnValue=2
strPrefix= "Critical - "
Else
If(warningReturn = 1) Then
returnValue=1
strPrefix= "Warning - "
Else
returnValue=0
strPrefix= "Ok - "
End If
End If
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetWarningValueFromRange().
'Descripton: Get perform value at Local Host.
'Input: warningValueRange.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetWarningValueFromRange(warningValue)
On Error Resume Next
lWarningValue = ""
uWarningValue = ""
temp1 = 0
temp1 = InStr(1, warningValue, ":")
if(temp1 > 0) then
lWarningTemp = Mid(warningValue, 1, temp1 -1)
uWarningTemp = Mid(warningValue, temp1 +1, len(warningValue) - temp1)
if(IsNumeric(lWarningTemp) or IsNumeric(uWarningTemp)) then
lWarningValue = lWarningTemp
uWarningValue = uWarningTemp
else
Wscript.Echo "Error! Arguments wrong, please verify -w parameter"
Wscript.Quit(intError)
Exit Function
end if
else
Wscript.Echo "Error! Arguments wrong, please verify -w parameter"
Wscript.Quit(intError)
Exit Function
end if
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetCriticalValueFromRange().
'Descripton: Get perform value at Local Host.
'Input: warningValueRange.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetCriticalValueFromRange(criticalValue)
On Error Resume Next
lCriticalValue = ""
uCriticalValue = ""
temp1 = 0
temp1 = InStr(1, criticalValue, ":")
if(temp1 > 0) then
lCriticalTemp = Mid(criticalValue, 1, temp1 -1)
uCriticalTemp = Mid(criticalValue, temp1 +1, len(criticalValue) - temp1)
if(IsNumeric(lCriticalTemp) or IsNumeric(uCriticalTemp)) then
lCriticalValue = lCriticalTemp
uCriticalValue = uCriticalTemp
else
Wscript.Echo "Error! Arguments wrong, please verify -c parameter"
Wscript.Quit(intError)
Exit Function
end if
else
WScript.Echo "Error! Arguments wrong, please verify -c parameter"
Wscript.Quit(intError)
Exit Function
end if
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_FormatData.
'Descripton: Format data the same as output.
'Input: service.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_FormatData(colWMI)
On Error Resume Next
strDisplay1 = ""
strDisplay2 = ""
strResultTemp3 = ""
strResultTemp4 = ""
For Each objWMI in colWMI
strName = objWMI.Name
strPropName = objWMI.Properties_(strProp).Name
intValue = objWMI.Properties_(strProp)
Dim strDSName
strDSName = f_FormatDSName(strName)
if((warningValue <> "") and (criticalValue <> "")) then
strDisplay1 = strName & " '" & strPropName & "'" & " = " & intValue & "; "
strDisplay2 = "'" &strDSName & "'" & "=" & intValue & ";" & warningValue & ";" & criticalValue & ";; "
If(InStr(1, warningValue, ":") > 0 Or InStr(1, criticalValue, ":") > 0) Then
f_GetPrefixWithRange(intValue)
Else
f_GetPrefix(intValue)
End If
strResultTemp3 = strResultTemp3 & strPrefix & strDisplay1
strResultTemp4 = strResultTemp4 & strDisplay2
if( intReturnTemp1 < returnValue) then
intReturnTemp1 = returnValue
end if
else
strResultTemp3 = strResultTemp3 & "OK - " & strName & " '" & strPropName & "'" & " = " & intValue & "; "
strResultTemp4 = ""
end if
Next
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetInstance.
'Descripton: Get infomation at Local Host.
'Input: instance.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_FormatDSName(strName)
On Error Resume Next
first = 1
position1 = 0
position1 = InStr(first, strName, "=")
Dim proc_name
proc_name = ""
If(position1 > 0) Then
proc_name = Mid(strName,position1+1,(Len(strName)-position1))
proc_name = Replace(proc_name,".","_")
proc_name = Replace(proc_name,"-","_")
proc_name = Mid(proc_name,1, 19)
Else
proc_name = Mid(strName,position1+1,(Len(strName)-position1))
proc_name = Replace(proc_name,".","_")
proc_name = Replace(proc_name,"-","_")
proc_name = Mid(proc_name,1, 19)
End If
f_FormatDSName = proc_name
Exit Function
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetInformation.
'Descripton: Get information data.
'Input: No.
'Output: Values.
'-------------------------------------------------------------------------------------------------
Function f_GetInformation()
On Error Resume Next
strResult = ""
strResult1 = ""
strResult2 = ""
intReturn = 0
If(instanceArraySize > 0 and (warningArraySize > 1 Or criticalArraySize > 1)) Then
for i = 0 to instanceArraySize -1
instance = instanceArray(i)
warningValue = warningArray(i)
criticalValue = criticalArray(i)
f_GetInstance(instance)
strResult1 = strResult1 & strResultTemp1
strResult2 = strResult2 & strResultTemp2
if intReturn < intReturnTemp then
intReturn = intReturnTemp
end if
Next
Else
for i = 0 to instanceArraySize -1
instance = instanceArray(i)
f_GetInstance(instance)
strResult1 = strResult1 & strResultTemp1
strResult2 = strResult2 & strResultTemp2
if intReturn < intReturnTemp then
intReturn = intReturnTemp
end if
Next
end if
if(strResult2 = "") then
strResult = strResult1
else
strResult = strResult1 & "|" & strResult2
end if
Wscript.Echo strResult
Wscript.Quit(intReturn)
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetInstances.
'Descripton: Get Prefix.
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetInstances()
On Error Resume Next
first = 1
position = 0
instanceArraySize = 0
position = InStr(first, strInst, ",")
if (position = 0) then
instanceTemp = strInst
InstanceArraySize = 1
ReDim instanceArray(instanceArraySize)
instanceArray(0) = instanceTemp
else
do while (position > 0)
instanceTemp = Mid(strInst,first,position - first)
instanceArraySize = instanceArraySize + 1
ReDim Preserve instanceArray(instanceArraySize)
instanceArray(instanceArraySize -1) = Trim(instanceTemp)
first = position + 1
position = InStr(first, strInst, ",")
loop
instanceTemp = Mid(strInst,first,len(strInst))
instanceArraySize = instanceArraySize + 1
ReDim Preserve instanceArray(instanceArraySize)
instanceArray(instanceArraySize -1) = Trim(instanceTemp)
end if
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_GetWarningCriticalValues.
'Descripton: Get Prefix.
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_GetWarningCriticalValues()
On Error Resume Next
position1 = 0
position2 = 0
position3 = 0
position4 = 0
temp1 = 1
temp2 = 1
warningArraySize = 0
criticalArraySize = 0
'get warning
position2 = InStr(temp1, warningValueString, ",")
If(position2 = 0) then
position2 = Len(warningValueString)+1
end if
If(position2 > position1) then
do while (position2 > position1)
warningPair = Mid(warningValueString, position1 + 1, (position2 - position1 -1))
warningArraySize = warningArraySize + 1
ReDim Preserve warningArray(warningArraySize)
warningArray(warningArraySize -1) = Trim(warningPair)
temp1 = position2 + 1
position1 = position2
position2 = InStr(temp1, warningValueString, ",")
If(position2 = 0) then
position2 = Len(warningValueString)+1
End If
loop
end If
If(Int(warningArraySize) < Int(instanceArraySize)) Then
ReDim Preserve warningArray(instanceArraySize)
For i = 0 To (instanceArraySize - warningArraySize - 1)
warningArray(warningArraySize +i) = warningArray(warningArraySize-1)
Next
warningArraySize = instanceArraySize
End If
'get critical
position4 = InStr(temp2, criticalValueString, ",")
If(position4 = 0) then
position4 = Len(criticalValueString)+1
end if
If(position4 > position3) then
do while (position4 > position3)
criticalPair = Mid(criticalValueString, position3 + 1, (position4 - position3 -1))
criticalArraySize = criticalArraySize + 1
ReDim Preserve criticalArray(criticalArraySize)
criticalArray(criticalArraySize -1) = Trim(criticalPair)
temp2 = position4 + 1
position3 = position4
position4 = InStr(temp2, criticalValueString, ",")
If(position4 = 0) then
position4 = Len(criticalValueString)+1
End If
loop
End If
If(Int(criticalArraySize) < Int(instanceArraySize)) Then
ReDim Preserve criticalArray(instanceArraySize)
For i = 0 To (instanceArraySize - criticalArraySize - 1)
criticalArray(criticalArraySize +i) = criticalArray(criticalArraySize-1)
Next
criticalArraySize = instanceArraySize
End If
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_LocalPerfValue.
'Descripton: Get perform value at Local Host.
'Input: No.
'Output: No.
'-------------------------------------------------------------------------------------------------
Function f_LocalPerfValue()
On Error Resume Next
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\" & strNameSpace)
f_Error()
'Set colInstances = GetObject("winmgmts:{impersonationLevel=impersonate}\\" & strComputer & "\" & strNameSpace).InstancesOf(strClass)
'For Each objInstance in colInstances
'Next
'f_Error()
f_GetInformation()
End Function
'-------------------------------------------------------------------------------------------------
'Function Name: f_RemotePerfValue.
'Descripton: Get perform values at Remote Host.
'Input: No.
'Output: Values.
'-------------------------------------------------------------------------------------------------
Function f_RemotePerfValue()
On Error Resume Next
Set objSWbemLocator = CreateObject("WbemScripting.SWbemLocator")
if (strDomain = "") then
Set objWMIService = objSWbemLocator.ConnectServer _
(strComputer, strNameSpace , strUser, strPass )
f_Error()
'Set colInstances = objSWbemLocator.ConnectServer(strComputer, strNamespace , strUser, strPass).InstancesOf(strClass)
'For Each objInstance in colInstances
'Next
'f_Error()
else
Set objWMIService = objSWbemLocator.ConnectServer _
(strComputer, strNameSpace , strUser, strPass,"MS_409","ntlmdomain:" + strDomain )
f_Error()
'Set colInstances = objSWbemLocator.ConnectServer(strComputer, strNamespace , strUser, strPass,"MS_409","ntlmdomain:" & strDomain ).InstancesOf(strClass)
'For Each objInstance in colInstances
'Next
'f_Error()
end if
objWMIService.Security_.ImpersonationLevel = 3
f_Error()
f_GetInformation()
End Function
'*************************************************************************************************
' Main Function
'*************************************************************************************************
'/////////////////////
strCommandName="check_counter_rawcount.vbs"
strDescription="Enumerate the needed windows host information."
'/////////////////////
strNameSpace = "root\cimv2"
f_GetAllArg()
tempCount = argcountcommand/2
f_Error()
strClass = ""
if ((UCase(arg(0))="-H") Or (UCase(arg(0))="--HELP")) and (argcountcommand=1) then
f_help()
else
if( ((argcountcommand Mod 2) = 0) and (3 < tempCount < 10)) then
strComputer = f_GetOneArg("-h")
strClass = f_GetOneArg("-class")
strProp = f_GetOneArg("-prop")
strInst = f_GetOneArg("-inst")
f_GetInstances()
warningValue = f_GetOneArg("-w")
warningValueString = f_GetOneArg("-w")
criticalValue = f_GetOneArg("-c")
criticalValueString = f_GetOneArg("-c")
If((warningValueString <> "") Or (criticalValueString <> "")) Then
f_GetWarningCriticalValues()
End if
strUser = f_GetOneArg("-user")
strPass = f_GetOneArg("-pass")
strDomain = f_GetOneArg("-domain")
if((strComputer = "") or (strClass = "") or (strProp = "") or (strInst = "")) then
Wscript.Echo "Error! Arguments wrong, require verify -h -class -prop -inst parameters"
Wscript.Quit(intError)
else
Select Case tempCount
Case 4:
f_LocalPerfValue()
Case 6:
if ((warningValue <> "") and (criticalValue <> "")) then
f_LocalPerfValue()
end if
if ((strUser <> "") and (strPass <> "")) then
f_RemotePerfValue()
else
Wscript.Echo "Error! Arguments wrong, please verify -user -pass or -w -c parameters"
Wscript.Quit(intError)
end if
Case 8:
if ((strUser <> "") and (strPass <> "") and (warningValue <> "") and (criticalValue <> "")) then
f_RemotePerfValue()
else
Wscript.Echo "Error! Arguments wrong for remote check, please verify -w -c -user -pass parameters"
Wscript.Quit(intError)
end if
Case 9:
if ((strUser <> "") and (strPass <> "") and (warningValue <> "") and (criticalValue <> "") and (strDomain <> "")) then
f_RemotePerfValue()
else
Wscript.Echo "Error! Arguments wrong for remote check, please verify -w -c -user -pass -domain parameters"
Wscript.Quit(intError)
end if
Case Else
Wscript.Echo "Error! Arguments wrong, please type -h for Help"
Wscript.Quit(intError)
End Select
end if
else
Wscript.Echo "Error! Arguments wrong, please type -h for Help"
Wscript.Quit(intError)
end if
end if