#!/bin/bash
#
# Copyright 2010, Pall Sigurdsson <palli@opensource.is>
#
# This script is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# This script is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
# About this script
#
# Checks uptime of a specified host, using NRPE is host is remote
HOSTN="localhost" # By default check localhost
CHECK_COMMAND="group_tool ls 0 default" # Default command to check selinux status
ok=0
warning=1
critical=2
unknown=3
print_help() {
echo "check_rhcs_cman version $VERSION"
echo "This plugin checks cman groups"
echo ""
echo "Usage: $0 [-H <host>] <-l LEVEL> <--group GROUP>"
echo ""
echo "Examples:"
echo "# check_rhcs_fencing.sh --level 0 --group default"
echo "# check_rhcs_fencing.sh --level 1 --group rgmanager"
}
#if [ $# -eq 0 ]; then
# print_help ;
# exit $UNKNOWN
#fi
# Parse arguments
while [ $# -gt 0 ]
do
case $1
in
-H)
HOSTN=$2
shift 2
;;
--group)
GROUP=$2
shift 2
;;
--level)
LEVEL=$2
shift 2
;;
*)
print_help ;
exit $UNKNOWN
;;
esac
done
if [ -z $GROUP ]; then
echo "ERROR - --group not specified"
print_help ;
exit $UNKNOWN
fi
if [ -z $LEVEL ]; then
echo "ERROR - --level not specified"
print_help ;
exit $UNKNOWN
fi
# We we are not checking localhost, lets get remote uptime via NRPE
if [ "$HOSTN" != "localhost" ]; then
export PATH=$PATH:/usr/lib/nagios/plugins:/usr/lib64/nagios/plugins:/nagios/usr/lib/nagios/plugins
CHECK_COMMAND="check_nrpe -H $HOSTN -c check_cman_group -a $LEVEL $GROUP"
fi
CHECK_COMMAND="group_tool ls $LEVEL $GROUP"
# group_tool ls
# type level name id state
# fence 0 default 00020001 none
# [1]
# dlm 1 rgmanager 00030001 none
#[1 2]
# Get the uptime, raise error if we are unsuccessful
OUTPUT=`$CHECK_COMMAND 2>&1`
RESULT=$?
SUMMARY=""
# group_tool should only return status 0 or 1
# if higher, then something unexpected occured
if [ $RESULT -ge 2 ]; then
echo "group_tool error: could not run command $CHECK_COMMAND"
echo "output:"
echo "$OUTPUT"
exit $unknown
fi
set -- $OUTPUT
type=$6
level=$7
name=$8
id=$9
state=${10}
# Check if group_tool command ran successfully
if [ $RESULT -ne 0 ]; then
echo "group_tool error: group $GROUP level $LEVEL not found."
echo "output:"
echo "$OUTPUT"
exit $critical
else
echo $OUTPUT | grep -qw "none"
RESULT=$?
if [ $RESULT -ne 0 ]; then
echo "group_tool error: group is in abnormal state. name=$name type=$type level=$level state=$state"
echo "output:"
echo "$OUTPUT"
exit $critical
else
echo "group_tool: group ok and in state 'none'. name=$name type=$type level=$level state=$state"
echo "output:"
echo "$OUTPUT"
exit $ok
fi
fi

View File

@ -5,3 +5,11 @@ command[get_rhcs_fencing]=test ! -p /tmp/fence_manual.fifo
command[check_rhcs_fencing]=/usr/lib64/nagios/plugins/check_rhcs_manualfencing.sh command[check_rhcs_fencing]=/usr/lib64/nagios/plugins/check_rhcs_manualfencing.sh
command[get_rhcs_cman_group]=/sbin/group_tool ls '$ARG1$' '$ARG2$'
command[get_rhcs_cman_group_default]=/sbin/group_tool ls 0 default
command[get_rhcs_cman_group_rgmanager]=/sbin/group_tool ls 1 rgmanager
command[check_rhcs_cman_group]=/usr/lib64/nagios/plugins/check_rhcs_cman_group.sh --level '$ARG1$' --group '$ARG2$'
command[check_rhcs_cman_group_default]=/usr/lib64/nagios/plugins/check_rhcs_cman_group.sh --level 0 --group default
command[check_rhcs_cman_group]_rgmanager=/usr/lib64/nagios/plugins/check_rhcs_cman_group.sh --level 1 --group rgmanager