check_ibm_bladecenter.py updated. Screenshots added

This commit is contained in:
Pall Sigurdsson 2011-06-21 18:55:10 +00:00
parent 2d2b20b120
commit 4c60683fd0
2 changed files with 31 additions and 30 deletions

61
check_ibm_bladecenter/check_ibm_bladecenter.py Executable file → Normal file
View File

@ -18,15 +18,7 @@
# About this script
#
# This script will check the status of a remote IBM Bladecenter via SNMP.
# Among other things the following are monitored:
# * General Health
# * Powermodule status
# * Temperature
# * Blade health
# * Switchmodule Health
# * Management Module health
# * Blowers
# * Chassis Sensors
# No real need to change anything below here
@ -87,6 +79,8 @@ parser.add_option("-p","--snmp_password", dest="snmp_password",
help="SNMP password (only with SNMP v3)", default=None)
parser.add_option("-l","--snmp_security_level", dest="snmp_seclevel",
help="SNMP security level (only with SNMP v3) (noAuthNoPriv|authNoPriv|authPriv)", default=None)
parser.add_option("-t","--snmp_timeout", dest="snmp_timeout",
help="Timeout in seconds for SNMP", default=10)
parser.add_option("-d","--debug", dest="debug",
help="Enable debugging (for troubleshooting", action="store_true", default=False)
@ -115,6 +109,7 @@ def set_snmp_options():
if opts.snmp_community is None:
parser.error("--snmp_community is required with --snmp_version=1|2c")
snmp_options = snmp_options + " -c %s " % opts.snmp_community
snmp_options += " -t %s " % (opts.snmp_timeout)
def error(errortext):
print "* Error: %s" % errortext
@ -269,7 +264,7 @@ def check_switchmodules():
add_long("Module%s health good.\n post=%s" % (myIndex,resultvalue))
else:
nagios_status(warning)
add_long("Module%s health bad.\n post=%s" % (myIndex, resultvalue) )
add_long("Module%s health bad(%s).\n post=%s" % (myIndex, healthstate,resultvalue) )
add_summary("Problem with Module %s. " % (myIndex))
if len(extrainfo) > int(myIndex):
myExtraInfo = extrainfo[int(myIndex)-1]
@ -441,7 +436,8 @@ def check_bladehealth():
myBladeid = row[bladeid]
mySeverity = row[severity]
myDescription = row[description]
myName = bladestate[i][6]
try: myName = bladestate[i][6]
except: myName = ""
if mySeverity == "(No severity)": continue
add_long( "blade%s (%s): %s %s" % (myBladeid,myName,mySeverity, myDescription) )
total_blades += 1
@ -470,7 +466,7 @@ def check_systemhealth():
elif systemhealthstat == "4":
nagios_status(critical)
add_summary("System-Level Error. ")
elif systemhealth == "0":
elif systemhealthstat == "0":
nagios_status(critical)
add_summary("Critical. ")
else:
@ -483,7 +479,8 @@ def check_systemhealth():
nagios_status(warning)
else:
nagios_status(critical)
add_summary( "%s: %s" % (row[severity], row[description]) )
add_summary( "%s. " % (row[description]) )
add_long( "* %s. " % (row[description]) )
def check_temperature():
# set some sensible defaults
@ -507,21 +504,25 @@ def check_temperature():
if __name__ == '__main__':
set_snmp_options()
if opts.mode == 'powermodules':
check_powermodules()
elif opts.mode == 'system-health':
check_systemhealth()
elif opts.mode == 'temperature':
check_temperature()
elif opts.mode == 'chassis-status':
check_chassis_status()
elif opts.mode == 'bladehealth':
check_bladehealth()
elif opts.mode == 'blowers':
check_blowers()
elif opts.mode == 'switchmodules':
check_switchmodules()
else:
parser.error("%s is not a valid option for --mode" % opts.mode)
try:
set_snmp_options()
if opts.mode == 'powermodules':
check_powermodules()
elif opts.mode == 'system-health':
check_systemhealth()
elif opts.mode == 'temperature':
check_temperature()
elif opts.mode == 'chassis-status':
check_chassis_status()
elif opts.mode == 'bladehealth':
check_bladehealth()
elif opts.mode == 'blowers':
check_blowers()
elif opts.mode == 'switchmodules':
check_switchmodules()
else:
parser.error("%s is not a valid option for --mode" % opts.mode)
except Exception, e:
print "Unhandled exception while running script: %s" % e
exit(unknown)
end()

Binary file not shown.

After