' WMI script to return the charge remaining in a laptop battery, using the
|
||
|
' EstimatedChargeRemaining property of the Win32_Battery class
|
||
|
' =========================================================
|
||
|
|
||
|
' Required Variables
|
||
|
Const PROGNAME = "check_printer"
|
||
|
Const VERSION = "0.0.1"
|
||
|
|
||
|
' Default settings for your script.
|
||
|
threshold_warning = 50
|
||
|
threshold_critical = 20
|
||
|
strComputer = "."
|
||
|
strPrinter = ""
|
||
|
|
||
|
' Create the NagiosPlugin object
|
||
|
Set np = New NagiosPlugin
|
||
|
|
||
|
' Define what args that should be used
|
||
|
np.add_arg "computer", "Computer name", 0
|
||
|
|
||
|
' If we have no args or arglist contains /help or not all of the required arguments are fulfilled show the usage output,.
|
||
|
If Args.Exists("help") Then
|
||
|
np.Usage
|
||
|
End If
|
||
|
|
||
|
' If we define /warning /critical on commandline it should override the script default.
|
||
|
If Args.Exists("computer") Then strComputer = Args("computer")
|
||
|
|
||
|
Set colInstances = np.simple_WMI_CIMV2(strComputer, "SELECT * FROM Win32_Printer")
|
||
|
return_code = OK
|
||
|
|
||
|
perf = ""
|
||
|
msg = ""
|
||
|
For Each objInstance In colInstances
|
||
|
msg = msg & "" & objInstance.Caption & _
|
||
|
" {Status: " & printer_status(objInstance.PrinterStatus) & _
|
||
|
", State: " & printer_state(objInstance.PrinterState) & "}; "
|
||
|
perf = perf & "status=" & objInstance.PrinterStatus & " state=" & objInstance.PrinterState & " "
|
||
|
return_code = np.escalate(return_code, check_status(objInstance.PrinterStatus))
|
||
|
return_code = np.escalate(return_code, check_state(objInstance.PrinterState))
|
||
|
Next
|
||
|
|
||
|
' Nice Exit with msg and exitcode
|
||
|
np.nagios_exit msg, return_code
|
||
|
|
||
|
|
||
|
Public Function printer_status(code)
|
||
|
Select Case code
|
||
|
case 1: printer_status = "Other"
|
||
|
case 2: printer_status = "Unknown"
|
||
|
case 3: printer_status = "Idle"
|
||
|
case 4: printer_status = "Printing"
|
||
|
case 5: printer_status = "WarmUp"
|
||
|
case 6: printer_status = "Stopped Printing"
|
||
|
case 7: printer_status = "Offline"
|
||
|
case else: printer_status = "Undefined"
|
||
|
End Select
|
||
|
End Function
|
||
|
|
||
|
Public Function check_status(code)
|
||
|
Select Case code
|
||
|
case 1: check_status = OK
|
||
|
case 2: check_status = UNKNOWN
|
||
|
case 3: check_status = OK
|
||
|
case 4: check_status = OK
|
||
|
case 5: check_status = OK
|
||
|
case 6: check_status = OK
|
||
|
case 7: check_status = CRITICAL
|
||
|
case else: check_status = UNKNOWN
|
||
|
End Select
|
||
|
End Function
|
||
|
|
||
|
Public Function printer_state(code)
|
||
|
Select Case code
|
||
|
case 0: printer_state = "Paused"
|
||
|
case 1: printer_state = "Error"
|
||
|
case 2: printer_state = "PendingDeletion"
|
||
|
case 3: printer_state = "PaperJam"
|
||
|
case 4: printer_state = "PaperOut"
|
||
|
case 5: printer_state = "ManualFeed"
|
||
|
case 6: printer_state = "PaperProblem"
|
||
|
case 7: printer_state = "Offline"
|
||
|
case 8: printer_state = "IOActive"
|
||
|
case 9: printer_state = "Busy"
|
||
|
case 10: printer_state = "Printing"
|
||
|
case 11: printer_state = "OutputBinFull"
|
||
|
case 12: printer_state = "NotAvailable"
|
||
|
case 13: printer_state = "Waiting"
|
||
|
case 14: printer_state = "Processing"
|
||
|
case 15: printer_state = "Initialization"
|
||
|
case 16: printer_state = "WarmingUp"
|
||
|
case 17: printer_state = "TonerLow"
|
||
|
case 18: printer_state = "NoToner"
|
||
|
case 19: printer_state = "PagePunt"
|
||
|
case 20: printer_state = "UserInterventionRequired"
|
||
|
case 21: printer_state = "OutofMemory"
|
||
|
case 22: printer_state = "DoorOpen"
|
||
|
case 23: printer_state = "Server_Unknown"
|
||
|
case 24: printer_state = "PowerSave"
|
||
|
case else: printer_state = "Undefined"
|
||
|
End Select
|
||
|
End Function
|
||
|
|
||
|
Public Function check_state(code)
|
||
|
Select Case code
|
||
|
case 0: check_state = OK
|
||
|
case 1: check_state = CRITICAL
|
||
|
case 2: check_state = OK
|
||
|
case 3: check_state = WARNING
|
||
|
case 4: check_state = CRITICAL
|
||
|
case 5: check_state = OK
|
||
|
case 6: check_state = CRITICAL
|
||
|
case 7: check_state = CRITICAL
|
||
|
case 8: check_state = OK
|
||
|
case 9: check_state = OK
|
||
|
case 10: check_state = OK
|
||
|
case 11: check_state = WARNING
|
||
|
case 12: check_state = UNKNOWN
|
||
|
case 13: check_state = OK
|
||
|
case 14: check_state = OK
|
||
|
case 15: check_state = OK
|
||
|
case 16: check_state = OK
|
||
|
case 17: check_state = WARNING
|
||
|
case 18: check_state = CRITICAL
|
||
|
case 19: check_state = OK
|
||
|
case 20: check_state = CRITICAL
|
||
|
case 21: check_state = CRITICAL
|
||
|
case 22: check_state = WARNING
|
||
|
case 23: check_state = CRITICAL
|
||
|
case 24: check_state = OK
|
||
|
case else: check_state = UNKNOWN
|
||
|
End Select
|
||
|