check_digitemp_adv/check_digitemp_adv.sh

263 lines
5.5 KiB
Bash
Executable File

#!/bin/bash
DIGITEMP="$(type -P digitemp_DS9097)"
PARAMETER="$*"
#Welche Werte soll es haben
#-c Kofigurationsdatei
#-s sensornummer
#-S Sensorname
#-w Warning
#-c|--crit critical
#-l|--list list all devices
#-p|--perfdata
#-h|--help
function hilfetext(){
cat <<- EOF
$(basename "$0") [OPTION...]
Options:
--config Path to .digitemprc. Default is the current directory
-s Display only the following SensorNumber
-S | --sensor Display only the following SensorID
-w | --warn Warning Value. Default is 40
-c | --crit Critical Value. Default is 50
-l | --list List all sensors
--celsius Display all temperatures in degree celsius (default)
--fahrenheit Display all temperatures in degree fahrenheit
-p | --perfdata show Performancedata
-h | --help Print this Help
EOF
}
function ParameterEvaluation(){
options=$(getopt -o s:S:w:c:lph --long config: --long sensor: --long warn: --long crit: --long list --long perfdata --long help --long celsius --long fahrenheit -- "$@")
#Option nicht verfügbar
[ "$?" -eq "0" ] || {
echo "Incorrect option provided"
exit 1
}
eval set -- "$options"
while true; do
case "$1" in
"--config")
shift; # The arg is next in position args
CONFIG_PATH="$1"
;;
"-s")
shift; # The arg is next in position args
#SENSOR_NUMBER="$1"
SENSOR_NUMBER+=" $1"
SENSORS+=" $1"
;;
"-S"|"--sensor")
shift; # The arg is next in position args
#SENSOR_ID="$1"
SENSOR_ID+=" $1"
SENSORS+=" $1"
;;
"-w"|"--warning")
shift; # The arg is next in position args
WARNING="$1"
;;
"-c"|"--critical")
shift; # The arg is next in position args
CRITICAL="$1"
;;
"-l"|"--list")
LIST="1"
;;
"--celsius")
CELSIUS="1"
;;
"--fahrenheit")
FAHRENHEIT="1"
;;
"-p"|"--perfdata")
PERFDATA="1"
;;
"-h"|"--help")
hilfetext
exit 0
;;
"--")
shift
break
;;
esac
shift
done
}
#Prüfen, ob digitemp installiert ist
if [ ! -x "$DIGITEMP" ]
then
echo "digitemp_DS9097 nicht gefunden"
exit 1
fi
#Wenn keine Option oder Argument angegeben wurde, wird die Hilfe ausgegeben
#if [ -z "$PARAMETER" ]
#then
# hilfetext
# exit 0
#fi
ParameterEvaluation "$0" "$@"
#Wenn Parameter CONFIG_PATH nicht gesetzt oder nicht vorhanden, dann wird das lokale gesucht
if [ ! -r "$CONFIG_PATH" ]
then
#DEBUG output
#echo "CONFIG_PATH \"$CONFIG_PATH\" nicht gefunden"
if [ ! -r "$(pwd)/.digitemprc" ]
then
echo "Config File not found"
exit 1
else
CONFIG_PATH="$(pwd)/.digitemprc"
fi
fi
#Wenn der Parameter WARNING nicht gesetzt ist, setze Standardwert
if [ -z "$WARNING" ]
then
WARNING="40"
fi
#Wenn der Parameter CRITICAL nicht gesetzt ist, setze Standardwert
if [ -z "$CRITICAL" ]
then
CRITICAL="50"
fi
#Wenn der Parameter WARNING > CRITICAL beende Programm
if [ "$WARNING" -gt "$CRITICAL" ]
then
echo "Parameter WARNING is greater then CRITICAL"
exit 1
fi
#Sollte weder --fahrenheit noch --celsius gesetzt sein, wird CELSIUS aktiviert
if [ "$FAHRENHEIT" = "" -a "$CELSIUS" = "" ]
then
CELSIUS="1"
fi
#Sollte --fahrenheit und --celsius gesetzt sein, wird das Script beednet
if [ "$FAHRENHEIT" = "1" -a "$CELSIUS" = "1" ]
then
echo 'Parameter "--celsius" and "--fahrenheit" gesetzt'
exit 1
fi
if [ "$LIST" = "1" ]
then
$DIGITEMP -c "$CONFIG_PATH" -a -o"Sensor %s: Serial %R" -q
exit 0
fi
#SENSORS="$SENSOR_NUMBER $SENSOR_ID"
#DEBUG
#echo "SENSORS: \"$SENSORS\""
STATUS_CRITICAL=0
STATUS_WARNING=0
STATUS_OK=0
for wert in $($DIGITEMP -c "$CONFIG_PATH" -a -o"%s;%R;%.0C;%.0F" -q)
do
sensor_id=$(echo $wert | cut -d ";" -f 1)
sensor_hex=$(echo $wert | cut -d ";" -f 2)
celsius=$(echo $wert | cut -d ";" -f 3)
fahrenheit=$(echo $wert | cut -d ";" -f 4)
#Debug flag
#echo -e "sensor_id: $sensor_id; sensor_hex: $sensor_hex; celsius: $celsius; fahrenheit: $fahrenheit"
#if [[ "$SENSORS" ~= "$sensor_id" ]]
#then
if [ "$CELSIUS" = "1" ]
then
if [ "$celsius" -ge "$CRITICAL" ]
then
STATUS_CRITICAL=$(( $STATUS_CRITICAL + 1 ))
#echo "ToDo: Ausgabe CRITICAL"
elif [ "$celsius" -ge "$WARNING" ]
then
STATUS_WARNING=$(( $STATUS_WARNING + 1 ))
#echo "ToDo: Ausgabe Warning"
else
STATUS_OK=$(( $STATUS_OK + 1 ))
#echo "ToDo: Ausgabe OK"
fi
OUTPUT+=" Sensor $sensor_hex is ${celsius}°C;"
OUTPUT_PERFDATA+="Sensor $sensor_id=$celsius;$WARNING;$CRITICAL "
fi
if [ "$FAHRENHEIT" = "1" ]
then
if [ "$fahrenheit" -ge "$CRITICAL" ]
then
STATUS_CRITICAL=$(( $STATUS_CRITICAL + 1 ))
#echo "ToDo: Ausgabe CRITICAL"
elif [ "$fahrenheit" -ge "$WARNING" ]
then
STATUS_WARNING=$(( $STATUS_WARNING + 1 ))
#echo "ToDo: Ausgabe Warning"
else
STATUS_OK=$(( $STATUS_OK + 1 ))
#echo "ToDo: Ausgabe OK"
fi
OUTPUT+=" Sensor $sensor_hex is ${fahrenheit}°F;"
OUTPUT_PERFDATA+="Sensor $sensor_id=$fahrenheit;$WARNING;$CRITICAL "
fi
done
#Debug output
#echo -e "STATUS_CRITICAL:\t$STATUS_CRITICAL\nSTATUS_WARNING:\t$STATUS_WARNING\nSTATUS_OK:\t$STATUS_OK"
#echo -e "OUTPUT: $OUTPUT"
#Wenn der schalter --perfdata gesetzt ist, wird die Ausgabe um $STATUS_OK, $STATUS_WARNING und $STATUS_CRITICAL erweitert
if [ "$PERFDATA" = "1" ]
then
OUTPUT="$OUTPUT | $OUTPUT_PERFDATA"
fi
##############################################
# Auswertung des Status und aufbereitung für nrpe
if [ ! "$STATUS_CRITICAL" = "0" ]
then
echo "CRITICAL -$OUTPUT"
exit 2
elif [ ! "$STATUS_WARNING" = "0" ]
then
echo "WARNING -$OUTPUT"
exit 1
elif [ ! "$STATUS_OK" = "0" ]
then
echo "OK -$OUTPUT"
exit 0
else
echo "UNKNOWN -$OUTPUT"
exit 3
fi